Want it Monday? Order within and choose Next Working Day Delivery

Free UK mainland delivery

On orders over £100

Open 8am to 4pm

Monday to Friday

Same day despatch

On orders before 3pm

Trade enquiries

Find out more

Static Caravan Ventilation and Replacement Air Vents

Static caravan ventilation is provided through a combination of floor, wall, ceiling and roof openings. These parts are not all interchangeable: a replacement must match the job of the original vent as well as its visible size and colour.

Do not block or reduce a permanent vent to cure a draught. Some openings provide combustion air or allow escaped LPG to disperse. If the purpose of a vent is uncertain, ask the caravan manufacturer or a competent specialist before altering it.

Common static caravan vent types

Vent typeWhere it is usedImportant checks
Floor ventThrough the caravan floor, sometimes with a mesh or separate cover.Opening diameter, tail size, free area, cover arrangement and whether it has a safety function.
Wall vent or grilleInternal or external wall panels.Required ventilation area, cut-out, fixing positions, weather protection and colour.
Gravity ventExternal outlet that opens under airflow.Tail diameter, flap movement, orientation and outside clearance.
Ceiling or roof ventHigh-level ventilation and roof-light assemblies.Roof opening, frame size, weather seal, fly screen and matching roof component.

Vent size and ventilation area are different

The outside dimensions of a grille tell you whether it may cover the opening, but they do not state how much air can pass through it. Louvres, mesh and moulded ribs all reduce the open area.

Where a product is marked 2205sqmm or 3000sqmm, that figure describes its stated ventilation area rather than the overall width or height. For example, MyStatic stocks a 2205sqmm vent with a 60mm tail and 3000sqmm wall vents. A larger-looking cover is not automatically an equivalent replacement.

What to record before ordering

  1. Photograph both sides. Include the visible cover and, where safely accessible, the tail or opening behind it.
  2. Measure the cut-out. Record the hole or opening that the vent passes through, not only the external flange.
  3. Measure the tail. Record its outside diameter, depth and shape.
  4. Record fixing centres. Measure centre to centre and note whether the replacement uses screws, clips or a push fit.
  5. Look for a stated free area. Copy any square-millimetre figure, part number or moulded marking.
  6. Identify the location and purpose. Note the room, nearby appliance and whether the vent passes through the floor, wall or roof.

Floor vents and LPG dispersal

LPG is heavier than air. NCC Code of Practice 502 requires dispersal points beneath LPG appliances and fittings in caravans covered by that scheme, arranged so escaped gas can ventilate beneath the caravan rather than enter a floor cavity.

This is why a floor opening should never be removed or covered simply because it creates a cold spot. A 75mm mesh floor vent may look like a simple trim part, but the required fitting and ventilation provision must be confirmed for the caravan.

Wall vents, hoods and gravity vents

External hoods can protect an opening from direct weather while still allowing airflow. Match the hood to the specified vent rather than assuming any cover with the same colour will work. MyStatic's 3000sqmm exterior vent hood is intended to accompany the corresponding stated ventilation area.

A gravity vent also needs enough room for its flap to move freely. Paint, sealant, dirt or a badly positioned replacement can stop it operating as designed.

Roof lights, ceiling vents and fly screens

Roof-light parts should be identified by the complete assembly and opening size. A ceiling frame, fly screen or cover may fit only a particular 170mm or tile-effect assembly. Check the roof component for cracking or water ingress and renew the correct seal in accordance with the manufacturer's instructions.

Cleaning and inspection

  • Keep grilles, mesh and gravity flaps clear of dust, insects and sealant.
  • Check external hoods after storms and whenever skirting or decking is changed.
  • Make sure caravan skirting still allows the underfloor ventilation required by the caravan and site.
  • Investigate condensation, appliance problems or repeated CO-alarm activation professionally rather than changing vents by trial and error.

Frequently asked questions

Can I fit a smaller vent if it covers the hole?

Not without confirmation. The replacement may provide less free ventilation even if its outside flange covers the opening.

Can I seal a floor vent during winter?

Do not block a permanent or safety-related vent. If cold air or water ingress is a problem, first identify the purpose of the opening and obtain the correct remedy.

Why does a replacement vent need a square-millimetre rating?

The figure helps compare the airflow provision rather than just the cosmetic size of the grille. Use it alongside the tail, cut-out and fixing measurements.

Find a replacement: browse MyStatic's static caravan floor, wall, ceiling and roof vents, or send us photographs and the measurements listed above.

This guide is informed by NCC Code of Practice 502, Holiday Caravans for the UK (December 2024), and current NCC technical guidance on ventilation compliance. It summarises relevant principles in MyStatic's own words and does not replace the caravan or appliance manufacturer's instructions.