Smoke, Heat and Carbon Monoxide Alarms for Static Caravans

Static caravans can need smoke, heat and carbon-monoxide alarms, but the three devices detect different hazards. The correct combination depends on the caravan, its fuel-burning appliances, how it is used and any requirements set by the manufacturer, park or fire-risk assessment.

This guide helps identify alarm types; it does not specify a complete system for every caravan. Holiday letting, a privately used holiday home and a newly manufactured caravan can be subject to different responsibilities.

Smoke, heat and carbon-monoxide alarms

Alarm typeWhat it detectsTypical location
Optical smoke alarmSmoke from a developing fire.Escape routes, bedrooms and living areas, subject to the system design and manufacturer's instructions.
Heat alarmA specified rise in temperature rather than smoke.Kitchens or other locations where cooking fumes could make a smoke alarm unsuitable.
Carbon-monoxide alarmCarbon monoxide produced by incomplete combustion.Rooms or compartments associated with fuel-burning appliances, positioned according to the alarm instructions.

A carbon-monoxide alarm is not a substitute for a smoke alarm, and a smoke alarm will not detect carbon monoxide. A complete arrangement may therefore contain more than one alarm type.

What current NCC guidance says

For holiday caravans covered by the NCC Manufacturer Approval Scheme, Code of Practice 502 specifies a Grade D1, category LD2 fire-alarm arrangement. The current code calls for smoke alarms in bedrooms, enclosed hallways and living areas, with a heat alarm in the kitchen, and for the alarms to be linked.

The code also specifies a carbon-monoxide alarm in each compartment containing a fuel-burning appliance, with a minimum of two CO alarms. If an alarm manufacturer's instructions prohibit installation inside an appliance compartment, the NCC guidance places it directly outside the compartment door.

These are manufacturing-scheme requirements and should not be turned into a one-size-fits-all replacement list for every older caravan. The original system, current alarm instructions and the caravan's use still matter.

Holiday caravans used for letting

Holiday caravans and lodges used for letting fall within fire-safety legislation. The person providing the accommodation should have a fire-risk assessment that determines the appropriate fire-detection and alarm system.

An NCC technical bulletin recommends a mains-powered and interlinked Grade D1, category LD2 system for holiday-letting accommodation. Its typical example uses a smoke alarm in the hallway, a heat alarm in the kitchen and a smoke alarm in the lounge unless an open-plan arrangement is covered by the heat alarm. The complete decision should come from the risk assessment, not from the room name alone.

Battery, mains and interlinked alarms

  • Replaceable-battery alarms need the specified battery and regular testing. The replacement interval shown in a product name normally refers to the expected battery arrangement, not permission to ignore testing.
  • Sealed-battery alarms have a non-replaceable battery intended for the stated service period. Replace the complete alarm at the end of its service life or earlier if the instructions require it.
  • Mains-powered alarms require a suitable electrical supply and professional installation. Backup-battery type, compatibility and interconnection must match the system design.
  • Interlinked alarms sound together when one unit detects a hazard. Only link models that the manufacturer confirms are compatible, using the approved wired or wireless arrangement.

The Firehawk FHN250RB mains smoke alarm and Firehawk FHN450RB mains heat alarm are listed as Grade D1 devices and can be interconnected with compatible Firehawk alarms. A competent installer should confirm whether these exact models and their backup arrangement meet the specification for the caravan and its pattern of use.

Choosing a replacement alarm

  1. Record the full model number, alarm type and manufacturing or replacement date.
  2. Check whether it is mains powered, battery powered or part of an interlinked system.
  3. For an interlinked system, identify every connected model and the wired or wireless interlink method.
  4. Check the alarm standard, system grade and any compatibility stated by the manufacturer.
  5. Use the positioning and clearance instructions supplied with the replacement; do not simply reuse an old fixing position without checking.

Testing and winter shutdowns

Test alarms at the intervals stated by their manufacturers and before a caravan is occupied after a shutdown. Replace any faulty, damaged, contaminated or end-of-life alarm. Where a mains system is isolated during winter, confirm how its standby supply should be managed; prolonged loss of mains power can affect some backup arrangements.

Activation of a carbon-monoxide alarm should be treated as a potential emergency. Follow the alarm instructions, move into fresh air and arrange appropriate checks of fuel-burning appliances rather than simply silencing the alarm.

Compare the available products: view MyStatic's static caravan smoke, heat and carbon-monoxide alarms, including battery and mains-powered models.

This guide is informed by NCC Code of Practice 502 (December 2024) and NCC technical bulletins on carbon-monoxide alarms and fire-detection systems. It paraphrases the relevant material and does not replace a fire-risk assessment, the alarm instructions or professional advice.