Want it Tomorrow? Order within and choose Next Working Day Delivery

Free UK mainland delivery

On orders over £100

Open 8am to 4pm

Monday to Friday

Same day despatch

On orders before 3pm

Trade enquiries

Find out more

How to Choose a Static Caravan Boiler or Water Heater

MyStatic static caravan guide

Choose the right hot-water system—not simply the nearest-looking replacement

A practical guide to LPG water heaters, LPG combi boilers and electric options for static caravans and holiday homes.

This guide is for static caravans and holiday homes. It is not advice for touring caravans, campervans or motorhomes. Residential park homes can also follow different requirements, so always tell the installer exactly what type of unit you have.

The correct appliance depends on more than its make or outside dimensions. Before choosing, establish what the system must do, the available fuel and electrical supply, the required flue arrangement, the water pressure and flow, and the appliance location. A competent installer should confirm compatibility before an order is placed.

Start with one question: hot water only, or heating too?

Hot water only

Choose a continuous-flow water heater when taps and showers need hot water but the caravan does not require the appliance to run radiators.

Hot water and radiators

Choose a combi boiler where one appliance must provide domestic hot water and a wet central-heating circuit.

One small local outlet

An electric storage or instantaneous heater may suit a sink or limited local demand, provided the electrical supply and circuit are adequate.

A water heater and a combi boiler are not interchangeable descriptions. A model such as the Morco EUP11RS or Rinnai 11i heats water only. A Morco GB24 IV or Ariston E-Combi One 24 also serves a central-heating system.

Compare the four main options

SystemWhat it providesWhere it can make senseChecks that matter
LPG continuous-flow water heaterHot water on demand, without a storage cylinder.Static caravans needing taps and showers supplied from a compact appliance.Required flow rate, LPG pressure, minimum water pressure, flue type, room location and whether 230V is needed.
LPG combi boilerHot water plus a wet radiator circuit.Holiday homes with central heating as well as normal hot-water demand.Heating load, hot-water output, system condition, condensate route, flue route, electrical supply and fitting kit.
Electric storage heaterA fixed volume of stored hot water.A sink or modest point-of-use demand where recovery time and capacity are acceptable.Tank size, recovery time, mounting position, space, electrical rating and expected simultaneous demand.
Electric instantaneous heaterHeats water as it passes through, with no tank.One outlet at a time where a suitably rated electrical circuit is available.Available amperage, dedicated circuit, achievable flow, inlet-water temperature and outlet limitations.

Flow rate: understand what the number means

Litres per minute alone can be misleading because output is normally stated at a particular temperature rise, written as ΔT. If incoming water is 10°C and the appliance produces a 35°C rise, the outlet temperature is about 45°C. Colder winter inlet water, a higher chosen outlet temperature or two outlets used together can reduce the useful flow.

For example, the Morco EUP11RS is listed at approximately 8 litres per minute at a 35°C rise, while the Morco GB24 IV combi is listed at approximately 10 litres per minute at the same rise. The Ariston Next Evo X 11 is listed at 11 litres per minute at a 25°C rise, which is a different test condition. Compare like with like rather than treating the largest headline number as automatically better.

Bigger is not automatically better. Increasing from a 6-litre to an 11-litre heater can change the gas-demand, flue, water-flow, electrical and space requirements. Ask the installer to confirm the whole installation can support the proposed model.

Current MyStatic examples

These examples show how specifications vary across the range. They are not blanket replacement recommendations; product revisions and installation requirements must be checked against the current product page and manufacturer instructions.

Example modelType and listed outputImportant distinction
Ferroli Pegaso Eco 6
MyStatic 408139
LPG water heater; up to 6 L/min.Open-chamber, natural-draught model with battery ignition and a vertical flue package. For static caravans/lodges, not touring caravans or motorhomes.
Morco EUP11RS
MyStatic 408205
Room-sealed LPG water heater; approx. 8 L/min at ΔT35.Fan-flued and 230V powered. The horizontal version uses its specified horizontal flue arrangement and is not converted into a vertical model.
Rinnai 11i
MyStatic 408171
Internal, room-sealed LPG continuous-flow heater.Horizontal flue package version; electronically controlled outlet-temperature range is listed as 37–65°C.
Rinnai 17CE
MyStatic 408160
External LPG continuous-flow heater; listed maximum 20 L/min.Designed for external installation, avoiding an internal combustion appliance location. Sizing still depends on demand, supply and manufacturer requirements.
Morco GB24 IV
MyStatic 408203
24kW LPG condensing combi; approx. 10 L/min at ΔT35.Provides hot water and central heating. Horizontal and vertical flue arrangements use different specified kits; the fitting kit is separate.
Ariston Aures Multi 9.5kW
MyStatic 406132
Instantaneous electric heater; minimum listed flow 2.1 L/min.Draws about 31.8A and serves one active outlet at a time, so the electrical circuit must be assessed before choosing it.
Ariston Andris Lux 15L 3kW
MyStatic 406112
15-litre electric storage heater.Compact stored-water option with a listed recovery time of about 18 minutes at ΔT45; capacity and mounting position must suit the intended use.

Browse MyStatic water heaters and boilers. Use the filters and full product specification, then have the proposed choice checked for the caravan.

Flues and appliance location

The flue is part of the appliance installation—not a generic accessory. Horizontal and vertical routes can require different manufacturer-approved terminals and kits. Do not assume an existing flue can be shortened, extended, mixed with a new model or reused because the diameter looks similar.

  • Room-sealed appliances take combustion air from outside and discharge products of combustion outside through their approved system.
  • Open-chamber appliances take combustion air from the room and depend on permanent ventilation and the correct natural-draught flue arrangement.
  • Only a suitable room-sealed appliance should be considered for a bath/shower room, toilet area or relevant sleeping accommodation, subject to the manufacturer’s instructions and installer assessment.
  • External units must be models specifically designed for external installation; an internal heater cannot simply be placed outdoors.

Static-caravan LPG and ventilation safety

Propane is commonly used for static caravans because cylinders and regulators are normally outside and propane remains usable at lower temperatures than butane. That does not mean every caravan has the same regulator pressure, pipework capacity or connection arrangement.

Permanent ventilation must not be blocked. Keep floor vents clear, and make sure any skirting around the caravan provides the ventilation required by the manufacturer and site arrangement. Flue terminals must remain unobstructed and correctly positioned. Never reduce ventilation to cure a draught.

Gas work is not a DIY job. Use a Gas Safe registered engineer whose qualifications cover LPG, static caravan/leisure accommodation work and the relevant appliance type. Ask for the appliance to be serviced annually and follow the manufacturer’s servicing instructions.

Replacement checklist

  1. Photograph the data plate. Capture the full make, model, gas category, heat input and any serial or product reference.
  2. Confirm the caravan type. State clearly that it is a static caravan/holiday home, or a residential park home if that is what you own.
  3. Identify what the appliance serves. Record whether it supplies hot water only or hot water and radiators.
  4. Confirm the fuel. Do not choose by the previous casing; establish LPG propane, natural gas or electricity from the installation and appliance plate.
  5. Record the installation position. Include clear photos of the cupboard or wall, nearby room use, ventilation openings, pipe connections and the outside terminal.
  6. Measure the available space. Height, width and depth are only the start; allow for service clearances, connection access and the correct flue route.
  7. Check water performance. The installer should assess dynamic water pressure and flow at the appliance, not rely solely on a static-pressure reading.
  8. Check power. Some LPG heaters use batteries; fan-flued heaters and combi boilers commonly need 230V. High-power electric units may need a dedicated circuit.
  9. Check what the listing includes. Appliance-only, horizontal-flue, vertical-flue and fitting-kit packages are different products.
  10. Get compatibility confirmed before ordering. Similar appearance, brand or nominal output is not evidence of a direct replacement.

Frequently asked questions

Can I replace a 6-litre heater with an 11-litre model?

Possibly, but not on capacity alone. The installer must confirm gas supply, ventilation, flue route, water pressure and flow, electrical requirements, dimensions and clearances.

Can I reuse the existing flue?

Only where the new appliance manufacturer explicitly approves that exact flue system and the installer confirms its condition and installation. A similar diameter or connection is not enough.

Horizontal or vertical flue—which do I need?

It depends on the appliance model, position and permitted terminal location. Buy the package specified for the planned route; do not assume one version converts to the other.

Is a room-sealed heater always the right choice?

Room-sealed appliances can offer more installation options, but the correct answer still depends on the room, terminal position, power supply, clearances and manufacturer instructions. Some locations require a suitable room-sealed design.

Can an electric heater replace LPG?

It can in some installations, but compare hot-water demand with the available electrical supply. A small storage heater has limited capacity; a 9.5kW instantaneous unit draws substantial current and must be assessed by a competent electrician.

Will this advice work for a touring caravan?

No. Touring caravans and motorhomes use different appliances, installation arrangements and approval requirements. Choose products specifically intended for those vehicles.

Need help narrowing the choice?

Send MyStatic the current appliance make and model, a clear data-plate photograph, labelled measurements and photos of the flue route and connections. We can help identify relevant products for your installer to approve.

Contact MyStatic  |  Shop water heating

Product specifications can change. The current product page, manufacturer instructions and competent installer’s assessment take priority over this general guide.